The loud sound emitted by a 2GIG GoControl panel (or the siren sound for three seconds, if an external siren is attached) when arming is due to UL supervision settings. When the commercial UL option is selected in the customer's monitoring settings, the panel emits an audible indicator of acknowledgment when an armin…
The panel can be connected to a Wi-Fi network by either manually selecting the network or using Wireless Protected Setup (WPS). Once the system is connected to Wi-Fi, Dual-Path communication can also be enabled. For more information about enabling Dual-Path, see Enable or disable Dual-Path communication remotely . …
PIR sensitivity settings By default, the Image Sensor is configured with a standard motion sensitivity profile Normal . The sensor can also be set to a more sensitive motion profile (i.e., High ) and a less sensitive profile with pet immunity for pets up to 40 lbs (i.e., Low ). The sensitivity can be configured …
Sensor restorals are sent if a sensor triggers an alarm and is then closed or reset before the system is disarmed. Important : Sensor restorals are forwarded only if the sensor is closed before disarming the panel. If the panel is disarmed with the sensor open, then the sensor is closed after disarming, a restoral i…
The content on this page has been written by a third party and is not maintained by Alarm.com. Any questions regarding the installation, maintenance, and/or usage instructions in this guide should be directed to the device manufacturer. To access the full installation guide, see 2GIG GC3 Panel - Installation Gui…
Each sensor (wireless or wired) installed in the system is programmed to a specific sensor number and sensor type (zone). The sensor number identifies the specific sensor when it is displayed on the Control Panel, recorded in the event log, or reported to the monitoring station. This allows pinpointing information…
Some features of the Alarm.com mobile app are available or unavailable depending on panel limitations. Arming app options Silent Arming Incompatible. Silent arming can only be done locally using the panel; remote commands adhere to the local setting. No Entry Delay Compatible. Remotely Bypass Sensors …
The guides attached to this page have been written by a third party and are not maintained by Alarm.com. Any questions regarding the installation, maintenance, and/or usage instructions in these guides should be directed to the device manufacturer. To download this guide directly to your device, click 2GIG GoContr…
The 2GIG-SMKT3-345 is a wireless Smoke/Heat/Freeze all in one sensor. When enrolling this device to the panel, repeat the Programming instructions from the attached installation guide for each of the three features using a different loop number for each feature. For example, the sensor is programmed into sensor 1 …
If Cell module not detected displays on a 2GIG GC3, perform the following steps to locally resolve the behavior. How to resolve: Verify compatible panel firmware Verify the panel firmware version is compatible with the module. Select Cell Radio Swap If the panel firmware version is compatible, select Cell Radi…