User code compatibility by panel
print icon

The following table lists the user code compatibility by panel models and notes any firmware (FW) version requirements. The Number of digits in a code is the number of digits supported by Alarm.com to be in a user code.

Note: If a panel (i.e., NX or DSC PowerSeries) supports more digits and is changed locally to use more digits than what Alarm.com supports, there will be unexpected behavior. 

Panel Maximum number of user codes Number of digits in a code
2GIG GoControl
  • Panel FW below 1.8: 7 
  • Panel FW versions 1.9 - 1.13: 32
  • Panel FW versions 1.14+: 64
4-digit user codes 
2GIG GC2e  64 

4-digit user codes

6-digit user codes option with firmware version 1.23+. Programmable in Q98 of panel programming.

2GIG GC3 / GC3e 

100

Note: Master Code, Duress Code, and Installer Code all count toward the limit.

4-digit user codes 

6-digit user codes option with firmware version 3.2.2+. Programmable in Q71 of panel programming.

2GIG EDGE

100

Note: Master Code, Duress Code, and Installer Code all count toward the limit.

4- or 6-digit user codes 

Programmable in section [Q102]

DSC Impassa 16 4-digit user codes 
DSC iotega 100 4-digit user codes 
DSC PowerSeries Neo
  • HS2016: 48
  • HS2032: 72 
  • HS2064/HS2128 non-E panel versions:
    • Module FW less than 185C: 94 
    • Module FW 185C+: 200 
  • HS2064E with version 1.2+: 
    • Module FW less than 185C: 94
    • Module between FW 185C - 187: 200 
    • Module FW 187+: 500
  • HS2128E with version 1.2+:
    • Module FW less than 185C: 94
    • Module between FW 185C - 187: 200 
    • Module FW 187+: 1000 

4- or 6-digit user codes 

On panel version 1.20+/module version 185c+, 8-digit user codes are also compatible.

Programmable in section [041]

DSC PowerSeries Pro 
  • HS3032: 72 
  • HS3128/HS3248: 1000 

4-, 6-, or 8- digit user codes 

Programmable in section [041]

DSC Touch 242 4-digit user codes 
Interlogix Concord 230 4-digit user codes 
Interlogix NX
  • NX4(v2): 8
  • NX6(v2): 40
  • NX8(v2): 99
  • NX8E: 240
4-digit user codes 
Interlogix Simon XT / XTi / XTi-5 / XTi-5i 9

4- or 6-digit user codes 

Programmable locally in the Access codes menu

Qolsys IQ Panel 242 4-digit user codes 
Qolsys IQ Panel 2 242

4-digit user codes 

6-digit user codes option with firmware version 2.3.0+

Qolsys IQ Hub / IQ Panel 4 / IQ4 Hub / IQ4 NS 242 4- or 6-digit user codes, 1 duress code per partition 
Qolsys IQ Pro  1000 4- or 6-digit user codes 
SEM - DSC PowerSeries
  • PC1616: 48
  • PC1832: 71
  • PC1864: 94

4-digit user codes

SEM - Honeywell/ADEMCO Vista
  • Vista 10p: 17
    • 15 General, 1 Installer, 1 System Master
  • Vista 15p: 33
    • 31 General, 1 Installer, 1 System Master
  • Vista 20p/21ip: 49
    • 45 General, 1 Installer, 1 System Master, 2 Partition Masters
4-digit user codes

 

Additional considerations

  • All user codes on a system must be the same length. For example, if a panel was updated from 4-digit to 6-digit user codes in programming, all current user codes add 00 at the end of each code.
  • Both 4-digit and 6-digit user code lengths are compatible with being updated remotely from Alarm.com.