2GIG GoControl - Monitoring Station Dialer Codes
print icon

Monitoring Station dialer codes are led with either a 1 or E to indicate the event signal and led with a 3 or R to indicate a restore signal. The event history on Alarm.com always displays the codes leading with a to indicate the event and 3 to indicate the restore. 

Reporting Zones

2GIG Type

Description

Type of Equipment

CID / Restore Codes

Comments

1

Entry/exit 1

Contact

1134 / 3134 (zone #)

-

2

Entry/exit 2

Contact

1134 / 3134 (zone #)

-

3

Perimeter

Contact / Glass Break

1131 / 3131 (zone #)

-

4

Interior follower

Motion / Contact

1132 / 3132 (zone #)

-

5

Day zone

Contact

1135 / 3135 (zone #)

1156 / 3156 (zone #)

Alarm Trouble

6

24 hour Silent panic

Button / Contact

1122 / 3122 (zone #)

-

7

24 hour audible alarm

Button / Contact

1123 / 3123 (zone #)

-

8

24 hour Auxiliary alarm

Contact

1150 / 3150 (zone #)

-

8

24 hour Auxiliary alarm

Emergency

1100 / 3100 (zone #)

Medical

8

24 hour Auxiliary alarm

Water

1154 / 3154 (zone #)

Water

8

24 hour Auxiliary alarm

Freeze

1159 / 3159 (zone #)

Freeze

8

24 hour Auxiliary alarm

High temperature

1158 / 3158 (zone #)

High temp

9

24 hour fire

Smoke /heat rise

1110 / 3110 (zone #)

-

10

Interior with delay

Motion / Contact

1132 / 3132 (zone #)

-

14

24 hour CO

CO detector

1162 / 3162 (zone #)

-

16

Fire with verification

Smoke detector

1110 / 3110 (zone #)

-

23

No response

Contact / motion

NO REPORT

-

24

Silent Burglary

Contact

1146 / 3146 (zone #)

-
  1. Types 1, 2, 3, 4, 5 (alarm), 7, 10 follow Burglary Bell Cutoff Timer
  2. Types 9, 14,16 follow Fire Bell Cutoff Timer
  3. Types 8 has no bell cutoff and will not sound external sounder if used
  4. Types 5 (trouble) system disarmed will cause trouble beep 6 per minute until silenced or restored
  5. Restores; types 1, 2, 3, 4, 5, 6, 7, 9, 10, 14, 16, 24…..  Restores depend on how swinger shutdown is set.  For example:
    • if swinger shutdown is set to two then the zone types above will send a restore if restores are enabled at bell cutoff or anytime after bell cutoff if the zone in question becomes good.
      • If the same zone trips again no restore will be sent at bell cutoff even if the zone is good or becomes good; The reason for this is the zone can’t trip again during the same arming period because the swinger count of two has been reached. 
      • However when you disarm the system if the zone is good then a restore will be sent.
      • If the zone is not good at disarm, a restore is never sent for the second trip.
    • If swinger shutdown is set to one then restore will never be sent after the zone trips because the swinger shutdown count has been reached and therefore the zone can’t trip again.
      • However if the zone is good at disarm a restore will be sent then for the trip while armed,
      • if the zone is not good at disarm a restore is never sent for that zone.

        Note: Types 9, 14, and 16 don’t participate in swinger shutdown so if the zone becomes good or is good at bell cutoff a restore is sent Type 8 since there is no bell cutoff for type 8 a restore is only sent when disarmed if the zone is good.

Other Events

Event

CID Code

Comment

Cellular Backup Failure 

 1354 / 3354

-

Zone Tamper

1383 / 3383 (zone #)

If the system is armed then the zone sends an alarm

Zone Loss Of Supervision

1381 / 3381 (zone #)

-

Zone Low Battery

1384 / 3384 (zone #)

-

Zone Bypass

1570 / 3570 (zone #)

-

Cross Zone Trouble

1378 / 3378 (zone #)

Zones 47 & 48 if enabled

Panel Tamper

1383 / 3383 zone 000

System state is disarmed.

ADC doesn’t send restore

Panel Tamper

1137 / 3137 zone 000

The system state is armed.

ADC doesn’t send restore

Panel Low Battery

1302 / 3302 zone 000

-

Panel Loss Of AC

1301 / 3301 zone 000

-

Panel Programming entry

1627 zone 000

Not sent by ADC

Panel Programming exit

1628 zone 000

Not sent by ADC

Panel Walk Test Start

1607 user # 001

ADC sends user 000

Panel Walk Test End

3607 user # 001

ADC sends user 000

Panel Telephone Fail / Fail To Communicate Via Telephone

1350 zone 000

ADC doesn’t send phone line restored

Panel Siren Supervision

1320 / 3320 zone 000

-

Panel RF Jam

1344 / 3344 zone 000

-

Panel Loss Of Supervision Of Short Range Radio

1381 / 3381 zone 000

This means RF receiver is not working or talking to panel.

This happens armed or disarmed it takes approx 4:00 minutes to detect. ADC doesn’t send this event.

Closing From Panel Touch Pad

3401 user #

User 000 sent for quick arming.

Opening From panel touchpad

1401 user #

-

Closing From KeyFob

3401 user # (51-58)

Keyfob’s 1-8 are considered users 51-58

Opening from keyfob

1401 user # (51-58)

Keyfob’s 1-8 are considered users 51-58

Console audible panic

1123 / 3123 zone 099

ADC doesn’t send restore. Restore sent at bell cutoff or disarm

Console Silent Panic

1122 zone 099

No restore sent by ADC or dialer

Console Fire

1115 / 3115 zone 095

ADC doesn’t send restore. Restore sent at bell cutoff or disarm

Console Medical (emergency)

1100 / 3100 zone 096

ADC doesn’t send restore. Restore sent at bell cutoff or disarm. No external siren if installed

RF keypad Police Audible

1123 / 3123 zone 059 – 062

RF keypads are zones 59-62 ADC doesn’t send restore.

Restore sent at bell cutoff or disarm

RF Keypad Police Silent

1122 zone 059 – 062

RF keypads are zones 59-62

RF keypad Fire

(dialer sends) 1115 zone 059 – 062

(ADC sends) 1115 zone 095

RF keypads are zones 59-62

Duress Code

1121 zone 092

-

Cancel

1406 (user#)

User number of user who disarmed

Exit Error

1457(user#) / 3457(zone#)

ADC sends user 0 dialer sends user # of who armed.  The dialer also sends restore with zone number at bell cutoff or disarm. ADC and dial both send an alarm for the zone that causes the exit error

Recent Closing

1459 (user#)

ADC sends user 0 dialer sends user # of who armed

Lack Of Usage

1654 / 3654 zone 000

-

Manual telephone test

1601  zone 000

-

Manual Cell Phone test

1601  zone 000

-

Automatic Test

1602  zone 000

-

GSM Radio Loss Of Network

1353 / 3353 000

Not sent by ADC

Listen In to follow

1606 000

This is sent on any alarm condition if two-way voice is enabled. There is no listen in sent for fire or CO and in fact if a listen-in session is in progress and there is a fire alarm or CO alarm the listen session is automatically ended. Also, if a fire or CO alarm is in progress, another alarm will not cause a listen in event to occur. The above is how the dialer works.

ADC works similarly with the following exception; ADC sends listen in to follow even for fire but the panel never dials the call and tells the ADC back end that it should release the two-way- line. If a silent alarm or duress is sent the CS can only use listen in mode, VOX and talk mode are automatically disabled.

 