Qolsys IQ Panel 2 – Dialer Delay & SIA Limits
Overview
Dialer delay determines how long the panel waits (in seconds) after an alarm before reporting to the monitoring center. Ranges depend on whether SIA Limits are enabled.
Dialer Delay Ranges
Mode | Default | Minimum | Maximum |
---|---|---|---|
SIA Limits Enabled | 30 seconds | 15 seconds | 45 seconds |
SIA Limits Disabled | 30 seconds | 0 seconds | 254 seconds |
Compliance tip: If your account must meet SIA control panel timing guidelines, keep SIA Limits enabled to enforce compliant ranges.
Panic Alarm Forwarding
The IQ Panel 2 treats some panics as immediate and others follow dialer delay. These behaviors are fixed in panel programming.
Follow Dialer Delay |
---|
Silent Panic |
Medical |
Police Panic |
Keyfob Emergency |
Send Immediately (No Delay) |
---|
Duress Code |
Fire |
Configure SIA Limits
Partner Portal
- Log into the Partner Portal.
- Open the customer account → Remote Toolkit → Command Catalog.
- Expand Timers → click SIA Limit.
- Set New Value to On (enable) or Off (disable) → Change.
MobileTech App
- Log into the MobileTech app.
- Select the customer account → Remote Toolkit → Command Catalog.
- Expand Timers → tap SIA Limit.
- Choose On or Off → tap Change.
Adjust Dialer Delay
Partner Portal
- In Remote Toolkit → Command Catalog → expand Arming Settings.
- Click Dialer Delay → enter desired seconds → Change.
MobileTech App
- Remote Toolkit → Command Catalog → expand Arming Settings.
- Tap Dialer Delay → enter desired seconds → Change.
Reminder: If SIA Limits are ON, your entry must fall within 15–45 seconds. If OFF, you may use 0–254 seconds (30s default).